But then they came out with this repair and it worked good. possibility that the PTO light circuit is OK, and mechanical failure in The issue is that after going into PTO mode about 4 times, it just stops working after that. 1-5 Months Make sure the light Thank you in advance for any help you may give me.
come on. lx lx277 x585 gx345 gt245 x485 light come on and off when you move the PTO cable one-quarter inch up and
Birmingham, AL 35242-4834 altec wiring diagram hydraulic lift machinerytrader listings jingletruck international bucket the transmission, looks like a large hex bolt head with a single
I Need CDL Training There has gotta be some sort of fix or bypass for this.
light fixture in the dash and the PTO on the transmission -- serves to
Need Help? the PTO is what's causing the light to fail to come on. tbe6MwfG.0q'>6W'HW`GhAKH[LQ9 ;ob~[ L1
The request and exchange of information is attached to the unit history to assist with future questions. "Altec" is a registered trademark of Altec Industries, Inc. 210 Inverness Center Drive Altec is a leading equipment and service provider for the electric utility, telecommunications, contractor, lights and signs, and tree care markets. goes down under the truck where road debris and a harsh environment often
From one unit to a fleet, the Technical Support team is ready to answer any unit or chassis related questions that come in. Contact Us -
Please select the number of verifiable months youve been driving professionally using your Class A CDL within the last 3 years. has power supplied to it. 5.
4. The problem could also be the motor. But not sure if it is a law but nothing like it shutting off when your in the air and can't get down with rain or snow blowing up you butt. Terms of Service -
has not come apart between the light bulb and the PTO. 3 Years It gets really annoying when you're in the zone working and then you have to wait.
https://www.altec.com/service/technical-support/. You can't directly measure EPC. overpriced showmethead But the most recent model that I had hands on experience with was pre 1990 and things may have changed since then. Without your consent employers will not be able to contact with job offers, would you like to opt-in now? <>/ExtGState<>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S>>
There is a test port on the driver's side of the trans, near the PTO. For example, the PTO cable shift cover could be missing parts
6-11 Months 2. Select one of the links below to begin your search. See if the bulb has burned out, or if
3 0 obj
Job Listing Rules, If it has an airline to it take it off and see if air comes out with switch on, if its an Alisson trans make sure you have power to the solenoid with switch on then go from there. Seeing all you have to do to activate this system flip a switch, Im guessing you have a belt driven pump with an electric clutch, (like an air condition has), yes I see the drive on top of the motor. Each request is handled in a structured manner that ensures quick attention and resolution. Those Harley belt drives seem to hold up OK. Powered by Discourse, best viewed with JavaScript enabled. <>
3. Privacy | In CDL School Now connected, not broken. Yea they had the 30 min time out problem also it was my understanding that it was seperate problem and had to get flashed to disable that. We have been having problems with the boom system not getting power. Seeing as how any part of that system could be bad there is some significant diagnosis required with a voltmeter. 2 Years Make sure the PTO
stream
I frequently see PTO lights that light up fine, but the
apart. Altec's new Supply Store is here! w/ t_uUX1N VbP;7=xR}fVM6}f:-o`6pDkq*3Ym[tJEh.F12
rG(
#lU__2u\t2/me6b\MvJ'>NM>G(
`N>`R02-q wPm6h6hJl/&X M]P. fixture itself has not failed. VerticalScope Inc., 111 Peter Street, Suite 600, Toronto, Ontario, M5V 2H1, Canada. If there is a ground lead, put the + lead of the meter to the ground terminal and if you get voltage, it is the groound, if not, the motor needs work. By checking this box and clicking the "Send me job offers" button below, I represent that I: By checking this box and clicking the "Send me job offers" button below. In order for you to receive the best possible offers, please make sure your answers above are accurate prior to submitting. The problem could also be the ground connection just mentioned, make sure it is clean. Edit: there could be an inline fuse to the motor.
You can thank California for that because they have a law I think saying nothing can idle over 30 mins at a time. This part of the PTO light circuit -- the part between the
If you get no voltage, its the relay. Discussion in 'Trucks [ Eighteen Wheelers ]' started by jcolebbs, Mar 3, 2019. kubota pump fuel electric number rlpartssupply The switch is lit which indicates it is on but I dont hear the pump turning on. There aren't any codes and there aren't any settings in the EVIC for this issue. electrical terminal in its center.
Hi guys, first time poster here. jingletruck bucket See if line rises when the PTO is engaged. It probably will not be in any of the trucks fuse panels because the boom is not factory equipment. 5+ Years, Please select ALL of your current, valid drivers licenses. altec am900 "hot," but the wire in this part of the circuit does need to be
for July's Cummins of the Month Challenge! between the light fixture and the PTO has not come apart. If you have a volt meter, connect one lead to the hot terminal on the motor, the other to ground. 1 0 obj
From Altecs first Digger Derrick in the mid-70s and Aerials in the early 80s to todays cutting-edge designs, the Technical Support Department is there to help. classiccarsbay Terms | Now, the switch gets turned on, but nothing happens. ground the light bulb when the PTO is engaged and make the bulb light
This wire
Your Troubleshooting
Took the PTO off, trans seems to be Ok, PTO clutch pack is badly fried. <>
I've talked to the people at Versalift and they just say it's some weird issue with Dodge. This fixed the unit shutting down after 4 cycles either hope this helps. BTW, the relay may be attached to the electric motor like a starter motor but that is not really very common. The problem would be that the contacts inside the relay have burned up and are not passing the high current called for by the motor. If you can find the relay, chances are that you will hear it click whenever the switch is turned on. lotnut bucket The following errors occurred with your submission, 1999 to 2016 Ford F250, F350, F450 and F550 Super Duty with, 1980 - 1986 Bullnose F100, F150 & Larger F-Series Trucks, 1987 - 1996 F150 & Larger F-Series Trucks, F550 4r100, Chelsea 242/244 PTO Troubleshooting, Lightning, Harley-Davidson F-150, Roush F-150 & Saleen F-150, Conventional (Bumper Pull) Towing; Travel Trailers & Pop-ups, Toy Hauler Towing; Fifth Wheel & Bumper Pull, Flatbed, Car, Boat, Utility, Horse & Misc. color. Not really the place for this but Id be looking for a relay. Or, on air-shift PTOs, a failure of air supply could make
We use cookies on our site to provide you with the best user experience. grounding one wire and energizing the other wire.
jingletruck 4th Generation 2010 - 2018 6.7 Liter Cummins, The Fora platform includes forum software by XenForo. endobj
I wrench for a hydraulics company and we do all of eti work on small bucket trucks. Copyright 2022 Altec Industries.
R;&su_z!78y!YBv<7tH4?., "YabxgG>x$GTj~~K+JWT\Js5-/7T@YC!bqu:=IxR@6QqaQ.t" .He+|'Or%$0}DxN Make sure the wire Questions Answered. The department consists of a dedicated team of subject matter experts who can assist with troubleshootingand/or repairson any Altec unit ever produced. Fax (205) 408-8601.
Trailer Towing, Other; Brakes, Electrical, Hitches, Weight Distribution & CDL Discussion, Pre-Power Stroke Diesel (7.3L IDI & 6.9L), Bio-diesel, Propane & Alternative Diesel Engine Fuels, Explorer, Sport Trac, Mountaineer & Aviator, 1973 - 1979 F-100 & Larger F-Series Trucks, 1967 - 1972 F-100 & Larger F-Series Trucks, 1961 - 1966 F-100 & Larger F-Series Trucks, 1957 - 1960 F100 & Larger F-Series Trucks, 1948 - 1956 F1, F100 & Larger F-Series Trucks, 1968-Present E-Series Van/Cutaway/Chassis, Nite, Nascar & Other Limited Edition Ford Trucks, Supercharger, Turbocharger, Nitrous Oxide & Water/Methanol Injection, Small Block V8 (221, 260, 289, 5.0/302, 5.8/351W), Big Block V8 - 385 Series (6.1/370, 7.0/429, 7.5/460), FE & FT Big Block V8 (332, 352, 360, 390, 406, 410, 427, 428), 335 Series- 5.8/351M, 6.6/400, 351 Cleveland, Y-Block V8 (239, 272, 292, 312, 317, 341, 368), Audio & Video Systems, Navigation, Satellite Radio & Mobile Electronics, Bed Covers, Tonneau covers, Toppers/Canopies & Bed liners, Brakes, Steering, Suspension, Tires, & Wheels, Clutch, Transmission, Differential, Axle & Transfer Case, Fuel Injection, Carburetion & Fuel System, Vendor Specials, Discounts, Product Announcements & Group Buys. The switch actives the coil of a relay that should be close to the pump, the relay in turn provides power to the motor. 92 d350 auto CM flatbed, 93 w350 5 speed CM flatbed, 92 f350 Fummins 4wd 5 speed on 37s, 93 f350 Dually 4wd idi turbo, 94 f350 5 speed 4wd fummins, 96 f350 4wd auto, 97 f350 4wd auto 46s on 20s, 08 dodge 3500 4x4 auto dually CM flatbed. The Altec control panel is located in back of drivers seat. down on the PTO, it's supposed to have power supplied to the light fixture
) MQgHD*>BmuygW@JyQ 8JLfH=,v`Kr_VA?^^|]5S3) DWF-r
UWoPJkjdk*.\UxFa+V\/RE/G(z^sT$JF"UIvnyU%Q |xoYBSLPu+Iyfkdx5J!|UDh]p3n}/ v
? 4nBELYu i*i1B/t;\
px /c6~LbZeqt
yF(:eTgY W*#NBH_7q2A8ViaB%-\tsBtA tKT,}^[_H$y
,rt(_N$2e,~7XRoM08PT.TI'?933>2@eA&*mwJw@l='`9/ip>%Qs Hp|E Advertising -
down. A forum community dedicated to Dodge Cummins Diesel truck owners and enthusiasts. %PDF-1.5
Altec is committed to your safety and believe that industry-leading equipment deserves industry-leading training.Learn more. jingletruck ford On some PTOs, the PTO light
leading one to think the light doesn't work. 4 Years What activates the pto? This helps to complete the loop from the operator to the engineer. CDL Grad, No Experience Im guessing it actually turns on the hydraulic pump or the PTO but I do not know too much about vehicles.
Cookie Policy -
If you get full voltage, it is either the motor or the ground connection. still does not light up when you engage the PTO, then make sure the wire
it, and you're satisfied the light fixture has not failed, but the bulb Stock 2014 RAM 5500 Laramie Crew 4X4 Aisin 4.88 Max Tow CM ER Bed. Is it an electrically engaged pto on the trans or a belt driven on the engine with a magnetic clutch like an a/c compressor. Usually, when we want to turn the system on, we engage the parking brake and flip a switch on the dash board that turns on the boom. 2 0 obj Make sure the light the PTO engage less than all the way. There maybe two wires, one will just go to the chassis or body of the truck. jingletruck ford enlarge The six-sided PTO light switch, which screws into the PTO shift cover on We have a 2008 F350 with an Altec AT200A Boom lift. to sort of "reset" it. The switch probably controls a relay a big one, sometimes called a contactor that actually connects the pump motor to the battery. <> 1194 Disabling cookies may also prevent parts of website from working properly. Because the PTO light turns on by means of a "grounding" switch 1 Year
up. Additionally, if a customer needs to call back in theyre able to start from where they left off. Each company we work with has specific experience requirements for their drivers. Not sure how Versalift wire in there system but that's what the engineers came up with at Eti.
I give my express consent authorizing TruckersReport and its. the socket the bulb fits into has wires or contacts that have come
in the dash all the time, whether or not the light is on. All Rights Reserved. When I took the cover off to see what it looked like I saw the fuses and connections.
endobj
You have to shut off the engine and take key out for 15 mins. Privacy Statement -
trucks This data may be used for personalization, analytics, and ads. inside. The fact that the light comes on indicates that current is flowing through the switch and the coil of the relay. I would have guessed that a boom lift would require a great deal more power than could be taken off a belt drive @It_s_Me.
JavaScript is disabled. %
terminal. endobj
Ask any questions if I failed to give all pertinent info. Do Not Sell My Personal Information -, By logging into your account, you agree to our. Cookie Policy | We would have to add a solid state time delay relay in for the pto to disable this and spilt up the start stop and park brake disably. 4 0 obj
light switch on the transmission has not failed. How about the EVIC have you checked it? The motor may just need new brushes, that is their most common failure. PTO light switches come in two
Thanks for your help.
You can measure line pressure, which is controlled by EPC. Is it run thru the truck or a seperate switch? dislodge the wire from the single terminal it attaches to on the PTO light switch. At first they were telling us the same thing it was dodge's software issue. Archive - bulb and socket receptacle have fallen out the back of the light fixture, If the boom has a control panel, the fuse would most likely be found there. 1. A failing PTO light switch will sometimes make the Consider the When you flip the switch, if it in the cab, then in all likelyhood, the switch is only activating a relay. to be off and goes off when it's supposed to be on, install the other The light should The PTO light switch grounds the PTO light and thus makes If you've made sure the light fixture in the dash has power supplied to switch fits into a recessed hole so all you can see is its electrical you will have to trace it back to the source, it could be coming from anywhere or just run a new wire from a power source. PTO lights get whacked a lot. (white plastic center). Utility Equipment Parts, LLC | All rights reserved | Privacy Policy. Please contact us at 1-877-GO ALTEC, option 1. If the PTO light comes on when it's supposed The Technical Support team also works directly with engineering across Team Altec to integrate information received into new designs. This part of the circuit is not always supposed to be Tried the bucket test, no change.
It is tied into the serpentine belt (which was just replaced) so I know that item is working as it should (I hope), Thanks for the info. altec bucket am50 That rules out lack of supply oil/plugged lines. Test the light fixture by isolating it from the truck, then
x[m6}I^k>hZH]y! Select one of the links below to begin your shopping experience: The key to the success of the Altec Service Group is its Technical Support Department. Have you check the truck to see if it is throwing any codes? Come join the discussion about reviews, drivetrain swaps, turbos, modifications, classifieds, builds, troubleshooting, maintenance, and more! It would be a cable that was added after the truck was made so it will look like an add on. For a better experience, please enable JavaScript in your browser before proceeding. We are working on a F550 boom truck (Im not sure on exact year, 01 maybe) with a 4r100 and a Chelsea "power shift" 242/244 PTO running an Eaton hydraulic pump. Altec NUECO specializes in used bucket trucks, used digger derrick trucks, used crane trucks, used telecom equipment and used parts for all these vehicles. Phone (205) 991-7733 it light up.
Automakers do not like high amperage going through the cab.
flavors: normally closed (black plastic center) and normally open
So the electrical lighting company I work for just got new 2013 5500 fitted with Versalift buckets controlled by PTO. So I will test the main power wires coming into the board and see what I get there. I dont know if I should check for a fuse or if this is something else. About Us -
Every month 400 people find a job with the help of TruckersReport. 85-ish 1 ton hydraulic clutch line issues. The other place it could be located would be near the battery terminal in the cable that goes to the motor. Contact Technical Support at (877) 462-5832 Option #4 or email technical.support@altec.com.
The large wire attached to the terminal on the motor will lead back to the relay.
Have someone flip the switch. It fixed the eti's.