When either float is disconnected, the alarm will sound and the Red Float Status LED will blink indicating that the float state has changed. If you are certain that no CO is being produced, a charging battery may be producing gaseous by-products capable of causing the CO detector to activate. Check the controller. Sk3182 Aquanot Spin 508 Installed System, Technical Data, Aquanot Spin 508 FM3165: 60 Hz, Installation Instructions, Aquanot 508 Spin FM3166: 60 Hz, Sales Slick, Monitor Products With Z Control, Aquanot Maintenance Free Batteries FM3303. (a) Check positions of rubber stops on the operational float rod and adjust if necessary. Batteries contain acid, and, 6. This is meant to be an aid to the installer in order to test the pump without having to reset it each time. This will lead to behaviors designed to purge air and remedy an air lock situation. Do not operate in > 80 F environment. A defective battery will never become fully charged and may damage the charging circuits of the controller. If you only see 5 Ghz networks, you may need to log into your dual band router to choose to broadcast the networks separately. sump The location must be within 6 (1.8 m) of the control box and battery. The LEDs have specific patterns and behaviors that differ from other products on the market. in septic tanks to pump effluent or in sewage pits to pump sewage. It will look like ZCTL_Fit_xxxx where xxxx is the first 4 digits of your Fits Device ID. Use the Mobile App (iOS and Android) Before you begin: These basic instructions will not detail every step, but provide an overview of what the app will do. When the float is lowered, the pump will turn off, but the yellow DC Pump LED will not persist. 2.4 Ghz network is required. Check flow of water incoming to sump.
Also, some of these by-products can cause a CO detector to falsely activate. (a) Check for low battery. After up to 1 minute, the Fit will restart and return to normal operation.
This returns the firmwares device configuration to the state in which it left the factory. This system is unique in that it has self-testing and communication features when connected to the Z Control Cloud. 4. This feature enables the sump pump alarm to provide instant alerts to homeowners whenever a flooding emergency occurs. However, there is no, guarantee that interference will not occur in a particular installation.
Self testing 12 Volt backup sump pump system. If this condition exists, the incoming water. This is because the sequence of prior events indicated that the operational float cant be trusted (such as lifting the high water float while the operational float is down this is illogical to the controller since water would always lift the operational float first), and the controller will rely on input from the high water float. Pump will stop running once battery is below minimum voltage threshold. TECHNOLOGY: This charger uses the latest switch mode technology available. The Fits alert history on the Z Control Cloud will also be updated with the firmware update information, and notification to email accounts will occur. Each pump is individually tested and achieves 35 GPM at 10 at 12.7 volts. The 508 is made by Zoeller in Indiana. PERFORMANCEThe DC pump performance at 12.7 Vdc. Battery box will accommodate a maximum battery size of 13-1/2 (34.3 cm) Length x 7 (17.8 cm) Width x 9-1/2 (24.1 cm) Height. Check for obstruction in pump preventing impeller from rotating. After 1-second splash activation prevention delay the pump will turn on, the alarm will sound, and the light will alert of high water. Positive (+) lead to positive terminal and black neg. If the primary pump is installed, disconnect power. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. Use the below links from your mobile device. 2. Clean if required. Upon first connecting to the cloud, the Fit controller may immediately update its firmware over the air (OTA), if an update is available. Check installation of the high water switch taking care that it is installed so that its on point is higher than the on point of the operational switch. Apply AC Power to the Fit. The second method is to use your mobile device or computer to connect to the Fit directly. its SSID) and its password. Made from non-corrodible polyethylene. Zoeller batteries have a 3 year warranty.
A pen or toothpick or similar is required to press the Z Contol button (See Figure A). - Increase the separation between the equipment and module / product. This is to purge a suspected air lock. For those unfamiliar with the product, behaviors in the Fit may initially seem unusual. This will silence the alarm. Ensure the O-ring is properly located on the check valve. Unplug the operational float and then hold the Test and Silence buttons together for 6 seconds. The primary sump pump and the controller should be on separate circuits. (b) If power has been restored and water in sump remains high check primary pump. A completely drained battery may require up to 24 hours for full recharge. The Aquanot Fit Controller is designed for use with Z Control. Now the app will provide several instruction screens about scanning the data matrix, joining the Fits network, and then LEAVING the app and how to come back. If an update is taking place, the Z Control LED will flicker for up to 1 minute while the update is downloaded. These pumps have not been investigated for use in swimming pools and marine areas. If the signal is questionable, your network may not be able to provide a stable connection for the Fit. Check out theZoeller YouTube Channelfor Webinars, Tips, Trainings, and Product Videos! Lift the Fits operational float switch. The Z Control LED should be solid within a minute indicating successful connection to the router and the Z Control Cloud. Soapy water is recommended as a lubricant. Install the Fit Controller (see Figure 3) by using the anchors provided. After 1 second splash activation prevention delay, the DC backup pump will run, and the alarm will sound after 1 more second. As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory listed circuit analyzer, which will indicate if the power, neutral and ground wires are correctly connected to your outlet. If they are not, call a qualified, licensed electrician. The advanced technology hardware and firmware in the Fit controller will recognize, attempt to remedy, and alarm for many conditions that have not previously been possible. equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is, encouraged to try to correct the interference by one or more of the following. If the operational float is up during high water, unit will alarm and high water float light will illuminate. The battery LED will be yellow during normal charging operation.
Most routers have a firewall built into them. PUMP: Designed and tested for reliability, the Aquanot 508 DC sump pump works alongside submersible or pedestal pumps to provide up to 6 hours of continuous high performance pumping when the primary pump power is interrupted or more capacity is needed. Hold silence button for 3 seconds to reset the Fit controller. (a) To silence alarm if alarm will not reset, unplug the charger from 115 V wall outlet, then disconnect the black lead from charger on negative (-) battery post. Diverting water stream against wall of basin usually corrects an air lock problem. The yellow LED can be cleared by holding the Silence button for 3 seconds to reset. The System Ready light will be green when the unit is plugged into the 115 V wall outlet. All Zoeller Pump products are made in the USA using 95% U.S. content, ensuring exceptional quality and maximum reliability. (b) If immediate usage is required, remove and replace dead battery with a fully recharged battery. Batteries contain acid, and caution must be taken when handling. Double check that you know the correct password and exactly how it is spelled, including capitalization. BATTERY CASE: The included battery case will accommodate maximum battery dimensions of 13 L x 7-1/2 W x 9-1/2 H (33 cm L x 19 cm W x 24 cm H) and fits all group size 27, 29 and 31 batteries. Parts that fail within the warranty period, that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Manufacturers option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. Get a reliable emergency backup battery pump system that fills the void when the primary pump underperforms or is unavailable due to a power failure. Inspect and test the system for proper operations at least every 3 months.*. For example, the DC Pump LED will stay Yellow after pumping water, alerting the homeowner of a DC pump-run event. TECHNOLOGY:This charger uses the latest switch mode technology available. Plug the controller and the primary pump into the wall outlet. Firmware Updates:The Fit is capable of OTA, or over the air firmware updates. Homeowners dont need to worry about manually recharging the battery or that they wont be aware that the pump lacks a power supply. (g) Make sure discharge piping is not blocked. Create a free account at zcontrolcloud.com. Disconnect the primary pump from its power source before touching any component in the sump pit. The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage. Open the Fit and explore current status, configuration settings, and commands available, such as Pump Test, Buzzer Test, Silence, etc. The self-testing technology ensures the pump is ready to perform and contributes to its long-term reliability. These materials should be retained for future, 1. The battery will indicate its condition when the controller has DC power. The Fits alert history on the Z Control Cloud will also be updated with the firmware upgrade information, and nofication to email accounts will occur. Can be held for 3+ seconds to reset (or clear) alarms and LEDs. Risk of electric shock. Installation and servicing of electrical circuits and hardware should be performed by a qualified, licensed electrician.
If there is an operational float fault diagnosed by the controller, you may notice that it no longer turns the pump on and off. Allow the pump to run a few minutes. size 27 deep-cycle battery, 175 minute reserve capacity, or larger, Do not let corrosion build up on the battery terminals, To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only). Testing for ground. Move the switch up and down, ensuring free movement without interference from any obstructions inside the sump or lid. For best cooling, install wall mount configuration. Primary sump pump included with ProPak model: 508-0006 with model 53, 508-0007 with model 98. These times are based on continuous pumping at 8 (2.4 m) of static head. Some battery types used in battery backup systems, regardless of brand or manufacturer, have the potential to give off gaseous by-products when charging. The installation of DC automatic backup pumps requires the use of a variable, level float switch for operation. Then, unplug the Fit controller from the 115 V wall outlet. Since the high water float does not have a sufficient pumping range, the controller will turn the pump off once 30 seconds have elapsed or the pump begins spinning in air. Further, advanced float logic enables the controller to sense other pumping issues such as a stuck float, allowing the system to take actions to prevent damage to equipment. These limits are designed, to provide reasonable protection against harmful interference in a residential, installation. The pump may go back to the ready run position in a very short period of time. Band steering may need to be temporarily turned off during setup. The LEDs will display information about the controller. Zoeller Pump Company provides the previous statements only as guidelines to help prevent false activation of the CO detector. Smart reporting to the cloud provides the ultimate peace of mind. Make certain the clamp is tight on the pipe to avoid slippage. In no way are these statements intended to supersede the instructions that accompany the detector, nor do they supersede advice from the CO detector manufacturer.If the audible alarm associated with your CO detector is activated, we recommend the following actions: REDARC BCDC124D DC Battery Charger WIRING DIAGRAM FOR DC-DC CHARGERS High current equipment such as compressor. Home > Backup Pump Systems > Aquanot Fit 508, PROFESSIONAL Series, self-testing, 12-volt DC battery backup system with built-in WiFi for Z Control connectivity. The preferred method of installation for backup pumps is shown in Figure 1. Another unique feature of the Zoeller battery backup 508 is the ability of the system to recharge automatically. Some of these by-products can produce a rotten egg odor. Lift the high water float. (g) Hold Silence/Reset button for 3 seconds to reset the controller and clear any alarms or indicators. The controller should be located at least 3 (1 m) above the sump. If the DC pump is unplugged or jammed, for example, a fault alarm will result. This revolutionary Aquanot sump pump offers the following: PUMP:Designed and tested for reliability, the Aquanot 508 DC sump pump works alongside submersible or pedestal pumps to provide up to 6 hours of continuous high-performance pumping when the primary pump power is interrupted or more capacity is needed. Refer to the parts list on page 3. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battary. Install the high water switch with the on level set at least 1 (2.5 cm) above the on level of the operational float using the supplied clamp. ocate the Fits Device ID and data matrix on the top sticker. By connecting the Fit to the Z Control Cloud using the built-in WiFi, the user can set up free alert messages via email, text, and mobile app push notifications. The LED will now be off, indicating the Fit is in AP Mode. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products.Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211, Attention: Customer Support Department to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty.MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Reconnect power to the primary sump pump. Use it in tandem with other pedestal or submersible pumps to deliver hours of uninterrupted service. When the captive screen opens (see Figure C in next section), use the Wifi Scan button to find the Wifi network you want the Fit to use, select it from the list provided at the bottom of the screen (you may need to scroll), and type the Passphrase in the field. (d) The alarm will sound approximately 1 second after the pump starts to run. If they are not, call a qualified, licensed electrician. Know what your WiFi network is named (i.e. This could take up to a minute or so. After up to 1 minute, the Fit will restart and return to normal operation. (f) The pump will shut off after the water level is lowered and the operational float drops to the off position. CONTROLLER: The Spin controller is an automatic charging and protection system, including a low battery indicator and alarm, self-testing technology, and an optional high water switch. It is the owners responsibility to check the battery and battery connection at least once a month. zoeller mafco It is recommended that the pit be 18" (45.7 cm) in diameter or larger to. Reconnect the controller and the primary pump to the AC wall outlets. Note that the charger may not begin charging for several minutes. Diagnostic logic will recognize and prevent several common issues. Select a location for the battery and the controller. All electrical and safety codes must be followed including the National Electrical Code and all applicable local codes. Slide the DC pump into the fitting, and tighten the hose clamp. Connect to a separate electrical circuit from the primary pump. This allows for an extremely efficient charger in a compact design. Occasionally, products are damaged during shipment. Take immediate action for personal safety as recommended in the CO detector literature.
Also, some of these by-products can cause a CO detector to falsely activate. (a) Check for low battery. After up to 1 minute, the Fit will restart and return to normal operation.


Most routers have a firewall built into them. PUMP: Designed and tested for reliability, the Aquanot 508 DC sump pump works alongside submersible or pedestal pumps to provide up to 6 hours of continuous high performance pumping when the primary pump power is interrupted or more capacity is needed. Hold silence button for 3 seconds to reset the Fit controller. (a) To silence alarm if alarm will not reset, unplug the charger from 115 V wall outlet, then disconnect the black lead from charger on negative (-) battery post. Diverting water stream against wall of basin usually corrects an air lock problem. The yellow LED can be cleared by holding the Silence button for 3 seconds to reset. The System Ready light will be green when the unit is plugged into the 115 V wall outlet. All Zoeller Pump products are made in the USA using 95% U.S. content, ensuring exceptional quality and maximum reliability. (b) If immediate usage is required, remove and replace dead battery with a fully recharged battery. Batteries contain acid, and caution must be taken when handling. Double check that you know the correct password and exactly how it is spelled, including capitalization. BATTERY CASE: The included battery case will accommodate maximum battery dimensions of 13 L x 7-1/2 W x 9-1/2 H (33 cm L x 19 cm W x 24 cm H) and fits all group size 27, 29 and 31 batteries. Parts that fail within the warranty period, that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Manufacturers option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. Get a reliable emergency backup battery pump system that fills the void when the primary pump underperforms or is unavailable due to a power failure. Inspect and test the system for proper operations at least every 3 months.*. For example, the DC Pump LED will stay Yellow after pumping water, alerting the homeowner of a DC pump-run event. TECHNOLOGY:This charger uses the latest switch mode technology available. Plug the controller and the primary pump into the wall outlet. Firmware Updates:The Fit is capable of OTA, or over the air firmware updates. Homeowners dont need to worry about manually recharging the battery or that they wont be aware that the pump lacks a power supply. (g) Make sure discharge piping is not blocked. Create a free account at zcontrolcloud.com. Disconnect the primary pump from its power source before touching any component in the sump pit. The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage. Open the Fit and explore current status, configuration settings, and commands available, such as Pump Test, Buzzer Test, Silence, etc. The self-testing technology ensures the pump is ready to perform and contributes to its long-term reliability. These materials should be retained for future, 1. The battery will indicate its condition when the controller has DC power. The Fits alert history on the Z Control Cloud will also be updated with the firmware upgrade information, and nofication to email accounts will occur. Can be held for 3+ seconds to reset (or clear) alarms and LEDs. Risk of electric shock. Installation and servicing of electrical circuits and hardware should be performed by a qualified, licensed electrician.
If there is an operational float fault diagnosed by the controller, you may notice that it no longer turns the pump on and off. Allow the pump to run a few minutes. size 27 deep-cycle battery, 175 minute reserve capacity, or larger, Do not let corrosion build up on the battery terminals, To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only). Testing for ground. Move the switch up and down, ensuring free movement without interference from any obstructions inside the sump or lid. For best cooling, install wall mount configuration. Primary sump pump included with ProPak model: 508-0006 with model 53, 508-0007 with model 98. These times are based on continuous pumping at 8 (2.4 m) of static head. Some battery types used in battery backup systems, regardless of brand or manufacturer, have the potential to give off gaseous by-products when charging. The installation of DC automatic backup pumps requires the use of a variable, level float switch for operation. Then, unplug the Fit controller from the 115 V wall outlet. Since the high water float does not have a sufficient pumping range, the controller will turn the pump off once 30 seconds have elapsed or the pump begins spinning in air. Further, advanced float logic enables the controller to sense other pumping issues such as a stuck float, allowing the system to take actions to prevent damage to equipment. These limits are designed, to provide reasonable protection against harmful interference in a residential, installation. The pump may go back to the ready run position in a very short period of time. Band steering may need to be temporarily turned off during setup. The LEDs will display information about the controller. Zoeller Pump Company provides the previous statements only as guidelines to help prevent false activation of the CO detector. Smart reporting to the cloud provides the ultimate peace of mind. Make certain the clamp is tight on the pipe to avoid slippage. In no way are these statements intended to supersede the instructions that accompany the detector, nor do they supersede advice from the CO detector manufacturer.If the audible alarm associated with your CO detector is activated, we recommend the following actions: REDARC BCDC124D DC Battery Charger WIRING DIAGRAM FOR DC-DC CHARGERS High current equipment such as compressor. Home > Backup Pump Systems > Aquanot Fit 508, PROFESSIONAL Series, self-testing, 12-volt DC battery backup system with built-in WiFi for Z Control connectivity. The preferred method of installation for backup pumps is shown in Figure 1. Another unique feature of the Zoeller battery backup 508 is the ability of the system to recharge automatically. Some of these by-products can produce a rotten egg odor. Lift the high water float. (g) Hold Silence/Reset button for 3 seconds to reset the controller and clear any alarms or indicators. The controller should be located at least 3 (1 m) above the sump. If the DC pump is unplugged or jammed, for example, a fault alarm will result. This revolutionary Aquanot sump pump offers the following: PUMP:Designed and tested for reliability, the Aquanot 508 DC sump pump works alongside submersible or pedestal pumps to provide up to 6 hours of continuous high-performance pumping when the primary pump power is interrupted or more capacity is needed. Refer to the parts list on page 3. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battary. Install the high water switch with the on level set at least 1 (2.5 cm) above the on level of the operational float using the supplied clamp. ocate the Fits Device ID and data matrix on the top sticker. By connecting the Fit to the Z Control Cloud using the built-in WiFi, the user can set up free alert messages via email, text, and mobile app push notifications. The LED will now be off, indicating the Fit is in AP Mode. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products.Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211, Attention: Customer Support Department to obtain any needed repair or replacement of part(s) or additional information pertaining to our warranty.MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Reconnect power to the primary sump pump. Use it in tandem with other pedestal or submersible pumps to deliver hours of uninterrupted service. When the captive screen opens (see Figure C in next section), use the Wifi Scan button to find the Wifi network you want the Fit to use, select it from the list provided at the bottom of the screen (you may need to scroll), and type the Passphrase in the field. (d) The alarm will sound approximately 1 second after the pump starts to run. If they are not, call a qualified, licensed electrician. Know what your WiFi network is named (i.e. This could take up to a minute or so. After up to 1 minute, the Fit will restart and return to normal operation. (f) The pump will shut off after the water level is lowered and the operational float drops to the off position. CONTROLLER: The Spin controller is an automatic charging and protection system, including a low battery indicator and alarm, self-testing technology, and an optional high water switch. It is the owners responsibility to check the battery and battery connection at least once a month. zoeller mafco It is recommended that the pit be 18" (45.7 cm) in diameter or larger to. Reconnect the controller and the primary pump to the AC wall outlets. Note that the charger may not begin charging for several minutes. Diagnostic logic will recognize and prevent several common issues. Select a location for the battery and the controller. All electrical and safety codes must be followed including the National Electrical Code and all applicable local codes. Slide the DC pump into the fitting, and tighten the hose clamp. Connect to a separate electrical circuit from the primary pump. This allows for an extremely efficient charger in a compact design. Occasionally, products are damaged during shipment. Take immediate action for personal safety as recommended in the CO detector literature.
