Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. A flow setting other than prescribed may affect the patient therapy. The device and accessories have not been evaluated for safety in an MR environment. Under certain circumstances, oxygen therapy can be hazardous. No degradation in performance across the operating voltage range . E . Red Service Required light is illuminated . The surface temperature of the exhaust vents on the bottom of the unit may exceed 105.8F (41C) under certain conditions. Your DeVilbiss concentrator is now ready for use, properly position the cannula with the nasal prongs facing upward, insert the prongsinto nose. Auxiliary Oxygen Port (Serial numbers starting with R, N, or B): Your concentrator is equipped with an auxiliary oxygen port that can be used to fill oxygen cylinders with an FDA-cleared cylinder filling device that is designed to use oxygen from a concentrator to fill a cylinder.
We have parts for legacy machines like the Puritan Bennett 492 or Healthdyne BX-3000 up to the Healthdyne Alliance and Devilbiss MC Series, all the way up to the latest machines like the Respironics EverFlo or Invacare Perfecto and Airsep VisionAire. JCR-255 Radio Despertador Digital AM FM con Vibrador Debajo de la Almohada Radio Despertador Digital AM/FM con Vibrador, Sound Link MW-2408 MW-1608 HYBRID ANALOG/DIGITAL MIXER Gua de inicio rpido Puede descargar el Manual del usuario en, _pdf583W Cool Control 1 l Advanced Cool Control de en fr it nl es pt Cool Control 1, SRT 82 Terrestrial HDMI Receiver For TV Terrestrial HDMI Receiver for your TV SRT 82 Picture similar User. 2022, Quickie-Wheelchairs.com offered by SouthwestMedical.com, LLC.
DeVilbiss Oxygen Concentrator Filters include the Bacteria Filter, 515 Filter, Cabin Filter, Intake Filter, Extended Life Intake Filter, and Compressor Filter. Do not apply liquid directly to the cabinet or utilize any petroleum-based solvents or cleaning agents. Upon verification of the warranty status, instructions will be issued. A soft-bristled brush dampened with water can be used to remove stubborn soil Dry the concentrator using a clean lint-free cloth if water was used to remove soil.
Mild dish soap (2 tbsp) and warm water (2 cups). There are many types of humidifiers, oxygen tubing and cannulas/masks that can be used with this device. Your physician prescribed supplemental oxygen for you because you are not getting enough oxygen from room air alone. PROVIDERS NOTES Cleaning and Disinfection When There is a Patient ChangeDeVilbiss Healthcare recommends that at least the following procedures be carried out by the manufacturer or a qualified third party between uses by different patients.NOTE If the following described complete processing of the concentrator by an appropriately trained individual is not possible, the device should not be used by another patient.NOTE If preventive maintenance is due at this time, these procedures should be carried out in addition to the servicing procedures. Oxygen concentrator circuit breaker activated . NOTE This warranty does not obligate DeVilbiss to provide a loaner unit during the time that an oxygen concentrator is undergoing repair.NOTE Replacement components are warranted for the unexpired portion of the original Limited Warranty.
Our company is operated by industry professionals with more than 35 years of direct experience in providing customers with all types of specialty wheelchairs. Installation of 515LF-607 low output flow meter package will cause the low flow alarm to not work and will prevent the device from meeting the requirements of ISO-80601-2-69:2014 Section 201.13.2.101.
If the suggested procedures do not help, switch to your reserve oxygen system and call your DeVilbiss homecare provider. NOTE The OSD performance at 41F (5C) to 95F (35C), 93% R.H. through voltage range on the 525DS verified at 670m.The maximum recommended flow is 3 LPM when an oxygen bottle is being filled with oxygen from the auxiliary oxygen port.Use of the 515LF-607 low output flow meter package or other low output flow meter accessory will prevent the device from meeting the requirements of ISO-80601-2-69:2014 Section 201.13.2.101.Specifications are subject to change without notice. Unapproved filters are used with the unit. Use disinfectants safely Always read the label and product information before use, Always wear personal protective equipment when performing this procedure Use suitable gloves and safety glasses Cover exposed skin on arms to prevent accidental contact with a bleach solution that has been applied to the concentrator. Visual and audible alarms indicate if the device is not meeting specifications or a failure has been detected. Read this entire guide before using your DeVilbiss concentrator. Our website requires JavaScript to be enabled to work properly.
Use only spare parts recommended by the manufacturer to ensure proper function and to avoid the risk of fire and burns.
This device contains electrical and/or electronic equipment. This ratio produces a one (1) part bleach to five (5) total parts solution (1:5). Use a different wall outlet if the situation occurs again .
Use of this device at an altitude above 13,123 feet (4000 meters) or above a temperature of 95F (35C) or greater than 93% relative humidity may affect the flow rate and the percentage of oxygen and consequently the quality of the therapy. devilbiss concentrator liter oxygen respiratory The use of a fire stop device as part of the oxygen accessories is optional and is not contraindicated for use with this device.
Look at the flow meter to see that the indicator ball on the flow meter drops to zero.
Oxygen makes it easier for a fire to start and spread. Should this occur, refer to the service manual for additional instructions. Keep body parts a minimum of 32 (81.2 cm) away from this area. Vitality Medical. If you feel discomfort or are experiencing a medical emergency while undergoing oxygen therapy, seek medical assistance immediately to avoid harm. Filters for Oxygen Concentrators manufactured by DeVilbiss. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the oxygen concentrator, including cables specified by the manufacturer. devilbiss oxygen concentrator repair service concentrators refurbished Also, do not forget that we have a full line of replacement filters for every make and model of Oxygen Concentrator and also CPAP and BIPAP machines! DeVilbiss Customer Service Contact InformationCustomer Service (USA): 800-338-1988International Department: 814-443-4881 /[emailprotected]Ordering Non-Warranty Replacement PartsOrder non-warranty parts and literature from your DeVilbiss provider. Failure to do so may cause an electrical safety hazard. We have the largest DeVilbiss 5 Liter Oxygen Concentrator parts catalog available. Check the exhaust area and make sure there is nothing restricting the unit exhaust. Some electromagnetic sources may not be apparent, if you notice any unexplained changes in the performance of this device, if it is making unusual or harsh sounds, disconnect the power cord and discontinue use. 1 . Do not attempt to defeat this safety feature.NOTE To check your oxygen concentrator and accessories for proper operation; 1.
Getting your DeVilbiss 5 Liter Oxygen Concentrator back into working condition is our top priority at Quickie Wheelchairs. Geriatric, pediatric or any other patient unable to communicate discomfort can require additional monitoring and/or a distributed alarm system to convey the information about the discomfort and/or the medical urgency to the responsible caregiver to avoid harm. Turn your unit Off. Switch to your reserve oxygen system and contact your DeVilbiss provider immediately. NOTE The disinfection process can only be completed by the manufacturer or by an appropriately trained individual. B . The OSD lights on the top panel are defined as follows: If the oxygen purity falls below the acceptable level: The green Normal Oxygen light will shut off, the yellow Low Oxygen light will illuminate, and an intermittent audible signal will sound.Refer to the Minor Troubleshooting section in this guide on page 9, and switch to your reserve oxygen system. All-Court Tennis / Basketball Wheelchairs. <>/ExtGState<>/Font<>/ProcSet[/PDF/Text]/Properties<>/XObject<>>>/Rotate 0/TrimBox[ 0 0 612 792]/Type/Page>> If proper flow is restored, clean or replace if necessary .
%PDF-1.6 NOTE There is no portion of the gas pathways through the concentrator that could be contaminated with body fluids under normal conditions.The device patient connection may unintentionally become contaminated with expired gases for a single fault condition i.e., a hose internal to the device becomes disconnected. Clean the exterior of the concentrator with a clean lint-free cloth. This warranty is limited to the Buyer of new equipment purchased directly from Drive DeVilbiss, or one of its Providers, Distributors, or Agents. Indications For UseThe DeVilbiss Oxygen Concentrator is intended for use as an oxygen concentrator to provide supplemental low flow oxygen therapy in the home, nursing homes, patient care facilities, etc. Detach the humidifier from the oxygen outlet. Unit operates . Use only water-based lotions or salves that are oxygen-compatible before and during oxygen therapy. Avoid over-saturating the cabinet seams so that no solution residue builds up in these areas. DeVilbiss warrants this equipment to be free from defects in workmanship and materials for three (3) years from date of factory shipment to the original purchaser, (typically the healthcare provider) unless contractually specified otherwise.
If the above remedies do not work, contact your DeVilbiss provider . 525DD-639: New filter door doesn't require gross particle filter. 3 .
Do not bring the device or accessories into a Magnetic Resonance (MR) environment as it may cause unacceptable risk to the patient or damage to the oxygen concentrator or MR medical devices. 3 . Comment document.getElementById("comment").setAttribute("id","a452959398799cea8435158a4a181e93");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. 5. Ensure the mains power cord is fully inserted into the concentrator connector (230-volt units) and the power cord plug is completely inserted into a fully functioning AC wall outlet. The very same quality rebuilt components that we install in our own Oxygen Concentrators that come with up to a full 5 year comprehensive warranty.
2.
Keep the oxygen concentrator and cannula at least 2 m (6.5 feet) from hot, sparking objects or naked sources of flame. 1 . Do not remove the concentrator cabinet. If not, follow the manufacturers instructions for attachment.NOTE Your healthcare provider should verify the compatibility of the oxygen concentrator and all of the parts used to connect to the patient before use.
The oxygen concentrator is used in home-type environments, homes, nursing homes, patient care facilities, etc.
Names and addresses can be obtained from the local municipality. Please enable JavaScript.
Use of harsh chemicals (including alcohol) is not recommended. Mikrobac forte or Terralin Protect) may also be used. Attach the oxygen tubing directly to the connector (Figure 1).